<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-22 20-43-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 76 dBuV NOSTALGI
Pilot RDS Phase Difference
6.0 kHz 3.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 68 kHz 19040 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 5,15 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Elamasi musiikkia. "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 68 kHz MIN: 11 kHz % above 76 kHz: 0,0053 Acquired: 2024/12/22 20.42.44 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 2,7 dBr AVE: 5,15 dBr % above 12,2 dBr: 0,0 Last value: 6,4 dBr (2024/12/22 20.42.44) 20.28 20.30 20.32 20.34 20.36 20.38 20.40 20.42 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]